docketcity.com
15-9916

FIRE-033-2025 Property Address: 1200 Deltona Boulevard, Deltona, FL 32725 Parcel ID: 8130-06-00-0020 Property Owner: Deltona Wellness LP P.O. Box 280 Lawrence, NY 11559-0280 Violation: A City of Deltona Ordinance, Chapter 42, Article IV, Fire Codes, Ch. 42-186. – Adopted Florida Fire Prevention Code 8th Edition, NFPA 1, Ch. 1.7.12.10 - No construction work shall proceed until the AHJ has reviewed the plans for compliance with the applicable codes and standards and the applicable permits have been issued. Violation: B Chapter 42, Article IV, Fire Codes, Ch. 42-186. – Adopted Florida Fire Prevention Code 8th Edition, NFPA 1, Ch. 4.1.3.2.2.5 - Buildings shall be designed and constructed to provide reasonable signage and lighting to identify hazards, exits, means of egress, and other building safety features. Violation: C Chapter 42, Article IV, Fire Codes, Ch. 42-186. – Adopted Florida Fire Prevention Code 8th Edition, NFPA 1, Ch. 13.1.1 - The AHJ shall have the authority to require that construction documents for all fire protection systems be submitted for review and approval and a permit be issued prior to the installation, rehabilitation, or modification. Further, the AHJ shall have the authority to require that full acceptance tests of the systems be performed in the AHJ's presence prior to final system certification. Violation: D Chapter 42, Article IV, Fire Codes, Ch. 42-186. – Adopted Florida Fire Prevention Code 8th Edition, NFPA 1, Ch. 11.1.8 - All panelboard and switchboards, pull boxes, junction boxes, switches, receptacles, and conduit bodies shall be provided with covers compatible with the box or conduit body construction and suitable for the conditions of use. Violation: E Chapter 42, Article IV, Fire Codes, Ch. 42-186. – Adopted Florida Fire Prevention Code 8th Edition, NFPA 1, Ch. 11.1.2.2 - Unless determined to present an imminent danger, existing electrical wiring, fixtures, appliances, and equipment shall be permitted to be maintained in accordance with the edition of NFPA 70 in effect at the time of the installation. Violation: F Chapter 42, Article IV, Fire Codes, Ch. 42-186. – Adopted Florida Fire Prevention Code 8th Edition, NFPA 1, Ch. 11.1.2.1 - All new electrical wiring, fixtures, appliances and equipment shall be installed in accordance with NFPA 70. Corrective Action: A Obtain an issued permit for the newly installed exterior door on the rear of Unit 53. Corrective Action: B Install room identification signage of the exterior of the door on the rear of the building containing electrical panels, labeled “Electrical Room.” Corrective Action: C Obtain an issued permit for the removal of the fire alarm control panel and modification of the tamper and waterflow switches. Corrective Action: D Provide an approved cover plate for the junction box & waterflow switch. Corrective Action: E Provide a neat, workman-like manner for the remaining telephone, low voltage & electrical wiring resulting from the removal of the fire alarm control panel. Remove all wiring no longer in use. Corrective Action: F Provide an approved junction box for the exposed sliced wiring going to the water flow switch. Captain / Assistant Fire Marshal Samuel Schaller

Code Violation New Business Introduced August 14, 2025
Committee
Special Magistrate
Introduced
August 14, 2025
On agenda
August 27, 2025

Where it was heard

Special Magistrate Aug 27, 2025