docketcity.com
15-10504

FIRE-030-2026 (A-E) Massey Property Address: 1240 Providence Boulevard, Suite 3, Deltona, FL 32725 Parcel ID: 8130-05-47-0420 Property Owner: Chulli Corp. 920 Grand Hilltop Drive Apopka, FL 32704 Violation: A City of Deltona Ordinance, Chapter 42, Article IV, Fire Codes, Ch. 42-186. – Adopted. Florida Fire Prevention Code 8th Edition, NFPA 1, CH. 11.1.5.1 – Extension cords shall be plugged directly not an approved receptacle, power, tap, or multiplug adapter and shall, except for approved multiplug extension fords, serve only one portable appliance. Corrective action: Discontinue the use of the extension cord behind the front counter and the rear storage room. Violation: B City of Deltona Ordinance, Chapter 42, Article IV, Fire Codes, Ch. 42-186. – Adopted. Florida Fire Prevention Code 8th Edition, NFPA 1, CH. 12.3.3.2 – Where required, fire-rated gypsum wallboard walls or ceilings that are damaged to the extent that through openings exist, the damaged gypsum wallboard shall be replaced or returned to the required level of fire resistance using a listed repair system or using materials and methods equivalent to the original construction. Corrective action: Reposition the ceiling tiles to eliminate openings in the rear storage closet and the main sales floor. Replace the damaged ceilings tiles in the rear storage closet and the main sales floor. Violation: C City of Deltona Ordinance, Chapter 42, Article IV, Fire Codes, Ch. 42-186. – Adopted. Florida Fire Prevention Code 8th Edition, NFPA 1, CH. 11.1.2.2 – Unless determined to present an imminent danger, existing electrical wiring, fixtures, appliances, and equipment shall be permitted to be maintained in accordance with the edition of 70 in effect at the time of installation. Corrective action: Resecure the light fixture to the ceiling in the rear storage closet. Violation: D City of Deltona Ordinance, Chapter 42, Article IV, Fire Codes, Ch. 42-186. – Adopted. Florida Fire Prevention Code 8th Edition, NFPA 1, CH. 13.6.1.1 – The selection, installation, inspection, maintenance, recharging, and testing of portable fire extinguishers shall be in accordance with NFPA 10 and Section 13.6. Corrective action: Contact your fire extinguisher contractor to have annual inspection/maintenance performed on fire extinguisher. Violation: E City of Deltona Ordinance, Chapter 42, Article IV, Fire Codes, Ch. 42-186. – Adopted. Florida Fire Prevention Code 8th Edition, NFPA 1, CH. 13.6.3.1.3.3.1 – Fire extinguishers shall be installed in locations where they are visible except as permitted by 13.6.3.1.3.3.2 [10:6.1.3.3.1]. Corrective action: Relocate the storage bins obstructing access to the fire extinguisher. Fire Safety Inspector Lisa Nadeau

Code Violation Old Business Introduced July 6, 2026

What this record is

Held by
Chulli Corp 2 records across this site
Runs until
no end date published in this record
Type
amendment
Field
Construction

Read automatically from the title of the official record. The source document below is authoritative.

Chulli Corp also holds

FIRE-030-2026 Property Address: 1240 Providence Boulevard, Suite 3, Deltona, FL 32725 Parcel ID: 8130-05-47-0420 Property Owner: Chulli Corp. 920 Gran… Deltona, FL
Committee
Special Magistrate
Introduced
July 6, 2026
On agenda
July 22, 2026

Where it was heard

Special Magistrate Jul 22, 2026