15-10373

FIRE-020-2026 Property Address: 3045 Mallard Drive, Deltona, FL 32738 Parcel ID: 8130-41-00-0020 Property Owner: Deltona Community Church of God Inc. 3045 Mallard Drive Deltona, FL 32738-8011 Violation: A City of Deltona Ordinance, Chapter 42, Article IV, Fire Codes, Ch. 42-186. - Adopted Florida Fire Prevention Code 8th Edition, NFPA 1, CH. 7.10.5.1* – Every sign required by 7.10.1.2, 7.10.8.1, other than where operations or processes required low level lighting levels, shall be suitably illuminated by a reliable light source. Externally and internally illuminated signs shall be legible in both the normal and emergency lighting mode. Corrective Action: Illuminated exit sign is not properly illuminated under emergency lighting power mode. Please repair it. Violation: B City of Deltona Ordinance, Chapter 42, Article IV, Fire Codes, Ch. 42-186. - Adopted Florida Fire Prevention Code 8th Edition, NFPA 1, CH. 11.1.8 – All panel board and switchboards, pull boxes, junction boxes, switches, receptacles, and conduit bodies shall be provided with covers compatible with the box or conduit body construction and suitable for the conditions of use. Corrective Action: Please provide an approved cover plate for the missing circuit in the breaker box. Please provide an approved cover plate for the other side of the 2-gang junction box. For both the Sanctuary’s rear and right-side doors. Violation: C City of Deltona Ordinance, Chapter 42, Article IV, Fire Codes, Ch. 42-186. - Adopted Florida Fire Prevention Code 8th Edition, NFPA 1, CH. 1.7.12.10 – No construction work shall proceed until the AHJ has reviewed the plans for compliance with the applicable codes and standards and the applicable permits have been issued. Corrective Action: Obtain an issued permit for the installation of the water heater in the kitchen. Permit can be obtained from the Deltona Building Services located at 2345 Providence Blvd. Permit must be applied for and obtained. Please contact our office once the permit is obtained. Violation: D City of Deltona Ordinance, Chapter 42, Article IV, Fire Codes, Ch. 42-186. - Adopted Florida Fire Prevention Code 8th Edition,NFPA 1, CH. 12.3.3.2 – Where required, fire-rated gypsum wallboard walls or ceilings that are damaged to the extent that through openings exist, the damaged gypsum wallboard shall be replaced or returned to the required level of fire resistance using a listed repair system or using materials and methods equivalent to the original construction. Corrective Action: Please replace the missing right and left decorative grills in the Sanctuary on the platform. Replace the missing ceiling tiles in the Sanctuary in the right-side closet of the platform. Violation: E City of Deltona Ordinance, Chapter 42, Article IV, Fire Codes, Ch. 42-186. - Adopted Florida Fire Prevention Code 8th Edition, NFPA 1, CH. 11.1.5.1 – Extension cords shall be plugged directly into an approved receptacle, power tap, or multiplug adapter and shall. Except for approved multiplug extension cords, serve only one portable appliance. Corrective Action: Please discontinue use of the extension cord running down to the TV from above the ceiling or relocate the TV. Violation: F City of Deltona Ordinance, Chapter 42, Article IV, Fire Codes, Ch. 42-186. - Adopted Florida Fire Prevention Code 8th Edition, NFPA 1, CH. 11.1.5.5 – Extension cords and flexible cords shall not be affixed to structures; extend through walls, ceilings, or floors, or under doors or floor coverings, or be subject to environmental or physical damage. Corrective Action: Please remove the electrical cord that is affixed to the wall and extending through the ceiling. Violation: G City of Deltona Ordinance, Chapter 42, Article IV, Fire Codes, Ch. 42-186. - Adopted Florida Fire Prevention Code 8th Edition, NFPA 1, CH. 11.1.2.2 – Unless determined to present an imminent danger, existing electrical wiring, fixtures, appliances, and equipment shall be permitted to be maintained in accordance with the edition of NFPA 70 in effect at the time of the installation. Corrective Action: Please remove the painter’s tape that is inside of the electrical junction box located at the Sanctuary’s right-side door. Fire Safety Inspector Lisa Nadeau

Code Violation New Business Introduced April 7, 2026
Committee
Special Magistrate
Introduced
April 7, 2026
On agenda
April 22, 2026

Where it was heard

Special Magistrate Apr 22, 2026