docketcity.com
15-10292

FIRE-009-2026 Property Address: 915 Doyle Road, Deltona, FL 32725 Parcel ID: 9106-09-00-0010 Property Owner: TCB Deltona LLC 353 N. Clark STE 3625 Chicago, IL 60654-3477 Violation: A City of Deltona Ordinance, Chapter 42, Article IV, Fire Codes, Ch. 42-186. - Adopted Florida Fire Prevention Code 8th Edition, NFPA 1, 13.1.6 – Fire Protection System Test and Maintenance Paperwork Required – Detailed records documenting all systems and equipment testing and maintenance shall be kept by the property owner and shall be made available upon request for review by the AHJ. Corrective Action: Please provide copies of the current fire alarm, fire backflow, and sprinkler systems inspection/maintenance reports for Buildings 100 and 300. Please provide a copy of the inspection report for the fire hydrant on site. Please send copies of inspection reports to fireprotection@deltonafl.gov. Violation: B City of Deltona Ordinance, Chapter 42, Article IV, Fire Codes, Ch. 42-186. - Adopted Florida Fire Prevention Code 8th Edition, NFPA 1, 4.1.3.2.2.5 – Buildings shall be designed and constructed to provide reasonable signage and lighting to identify hazards, exits means of egress and other building safety features. Corrective Action: Please replace the faded “FACP Inside” signage on the fire alarm control box on the exterior of building 100. Violation: C City of Deltona Ordinance, Chapter 42, Article IV, Fire Codes, Ch. 42-186. - Adopted Florida Fire Prevention Code 8th Edition, NFPA 1, 11.1.7.3.1 – Each disconnecting means shall be legibly marked to indicate its purpose unless located and arranged so the purpose is evident. In other than one-or-two- family dwellings, the marking shall include the identification of the circuit source that supplies the disconnecting means. The marking shall be of sufficient durability to withstand the environment involved. Corrective Action: Please identify and relabel the meter boxes with the missing suite numbers – Buildings 100 and 300. Violation: D City of Deltona Ordinance, Chapter 42, Article IV, Fire Codes, Ch. 42-186. - Adopted Florida Fire Prevention Code 8th Edition, NFPA 1, 10.11.1.6 – Address numbers for suites units etc. within a multiple tenant building or complex shall be individually identified in a manner approved by the AHJ, however shall be at least 6 in. (152.4mm) in height for all other buildings, structures, or portions thereof. Corrective Action: Provide/maintain a minimum 6” height numbers which are clearly visible from the street for Suite 301 and 306. Numbers shall be contrasting with background. Please replace the suite number on the rear of Quest Diagnostics to read “305” and not “303”. Fire Safety Inspector Lisa Nadeau

Code Violation New Business Introduced February 11, 2026
Committee
Special Magistrate
Introduced
February 11, 2026
On agenda
February 25, 2026

Where it was heard

Special Magistrate Feb 25, 2026