15-10081
FIRE-028-2025 Massey Property Address: 1644 Providence Boulevard, Deltona, FL 32725 Parcel ID: 8130-14-06-0010 Property Owner: Danford Enterprises LTD KA Crawford LLC 8608 Autumn Lake Trail Mckinney, TX 75071 Violation: A City of Deltona Ordinance, Chapter 42, Article IV, Fire Codes, Ch. 42-186. – Adopted. Florida Fire Prevention Code 8th Edition, NFPA 1, Ch. 10.11.1.6 – Address numbers for suites units etc, within a multiple tenant building or complex shall be individually identified in a manner approved by the AHJ, however shall not be less than 3 in. in height for residential and at least 6 in. in height for all other buildings, structures, or portions thereof. Corrective action: Provide/maintain a minimum 6" height address numbers (1644) on the rear door of the building. Numbers shall be contrasting with background. Violation: B City of Deltona Ordinance, Chapter 42, Article IV, Fire Codes, Ch. 42-186. – Adopted. Florida Fire Prevention Code 8th Edition, NFPA 1, Ch. 1.7.12.10 - No construction work shall proceed until the AHJ has reviewed the plans for compliance with the applicable codes and standards and the applicable permits have been issued. Corrective action: : Obtain an issued building permit for the following items. - Construction of new interior walls. - Installation of new electrical receptacle for self-venting fryer. - Installation of new electrical receptacles located on sales floor walls, ceiling, and cabinets. Violation: C City of Deltona Ordinance, Chapter 42, Article IV, Fire Codes, Ch. 42-186. – Adopted. Florida Fire Prevention Code 8th Edition, NFPA 1, Ch. 13.1.1 - The AHJ shall have the authority to require that construction documents for all fire protection systems be submitted for review and approval and a permit be issued prior to the installation, rehabilitation, or modification. Corrective action: Obtain an issued permit for the removal of the fire alarm system. Violation: D City of Deltona Ordinance,Chapter 42, Article IV, Fire Codes, Ch. 42-186. – Adopted. Florida Fire Prevention Code 8th Edition, NFPA 1, Ch. 1.7.12.1 - The AHJ shall have the authority to require plans and specifications to ensure compliance with applicable codes and standards. Corrective action: Provide the manufacturer’s specifications for the following items - RESFAB self-venting fryer. - Small cooking appliance located in kitchen. Violation: E City of Deltona Ordinance, Chapter 42, Article IV, Fire Codes, Ch. 42-186. – Adopted. Florida Fire Prevention Code 8th Edition, NFPA 1, Ch. 14.4.1 - Means of egress shall be continuously maintained free of all obstructions or impediments to full instant use in the case of fire or other emergency. Corrective action: Remove wall obstructing means of egress in kitchen OR obtain an issued building permit for the construction of the wall. Fire Safety Inspector Ajorie Bailey
- Committee
- Special Magistrate
- Introduced
- November 5, 2025
- On agenda
- November 25, 2025